A 30 by 24 foot crawl space with 6 piers needs about 922 sq ft of liner — 1,014 sq ft with 10% waste, or 1 roll of 12 by 100 feet — plus 138 feet of tape, 31 termination-bar pieces and 216 fasteners. Enter your crawl space below for your exact count.

Your crawl space
liner = floor + walls (perimeter x run-up) + pier wraps + seam laps · rolls = ceil(liner with waste / roll area) · tape = seams + perimeter · termination bar = perimeter / 42 in · fasteners every 6 in

Model code (IRC R408.3) asks for a Class I vapor retarder over exposed earth, joints lapped at least 6 in and sealed or taped, and edges extended at least 6 in up the stem wall and attached and sealed. The 12 in laps and run-up used here are a common stricter practice — check your local code. Roll sizes and the tape and bar sizes are typical, not one maker's list.

Estimates only — not a code ruling. Thickness is a permeance question, not a code number: check the liner's data sheet for its ASTM E1745 class and your local code for any thickness it names.

How the crawl space vapor barrier calculator works

The liner is more than the floor. This calculator adds four parts: the floor area (length x width), the wall run-up (perimeter x run-up height), a wrap around every support pier (pier perimeter x pier height), and the seam laps where sheets overlap (seam count x sheet length x overlap). Liner = floor + walls + pier wraps + seam laps, then a waste allowance of 10 to 20% on top — the worksheet method the trade uses, where the total to order is (ground + wall) x an overage factor. Rolls are the liner with waste divided by the roll area, rounded up: a 12 by 100 foot roll covers 1,200 sq ft, a 10 by 100 covers 1,000, and a 20 by 100 covers 2,000.

Worked example: a 30 by 24 foot crawl space with 6 piers, the liner run 12 inches up the walls and 12 inch laps at the seams. Floor 720 sq ft, walls 108 ft of perimeter x 1 ft = 108 sq ft, pier wraps 6 piers x (64 in perimeter x 24 in tall) = 64 sq ft, and one seam of 30 ft x 12 in = 30 sq ft of laps — 922 sq ft of liner, or 1,014 sq ft with 10% waste, which is 1 roll of 12 by 100 feet. Seam tape is the seam length plus the perimeter for the edge seal (30 + 108 = 138 ft, or 1 roll of 180 ft), termination bar is the perimeter in 42 inch pieces (108 / 3.5 = 31 pieces), and fasteners run every 6 inches along the bar (108 x 2 = 216).

Common mistakes: ordering the floor area only and running short on the walls, piers and laps; using the 6 inch code-minimum lap where the job needs 12 inches; and picking liner by thickness alone — the model code requires a Class I vapor retarder, which is a permeance rating of 0.1 perm or less, not a thickness. Six-mil polyethylene is the usual minimum for a crawl space ground cover, while 10 and 20 mil reinforced liners buy puncture resistance for spaces you will walk in. Wider rolls mean fewer seams, but a 20 foot roll is heavy to carry through a crawl space hatch.

liner = floor + walls + pier wraps + seam laps · rolls = ceil(liner x (1 + waste%) / roll area) · tape = seams + perimeter · termination bar = perimeter / 42 in · fasteners = perimeter x 2 (every 6 in)

Related tools

Above grade, the same job is wall wrap — see the House Wrap Calculator. For the floor above the crawl space, see the Insulation Roll Calculator, and for water coming through the walls, the Basement Waterproofing Cost Calculator.

Crawl space vapor barrier calculator FAQ

How much vapor barrier do I need for my crawl space?

Floor area plus wall run-up plus pier wraps plus seam laps, then 10 to 20% waste. A 30 by 24 foot crawl space with 6 piers, 12 inch run-up and 12 inch laps needs 922 sq ft of liner — 1,014 sq ft with waste, or 1 roll of 12 by 100 feet.

How far up the wall should the vapor barrier go?

The model code (IRC R408.3) sets 6 inches as the least, with the edge attached and sealed. Many installers run 12 inches up the stem wall, and some state codes ask for 12 — check your local code before you buy.

How much overlap do vapor barrier seams need?

The model code requires a 6 inch minimum lap, sealed or taped. The DOE weatherization guide and some state codes recommend 12 inches, which is the default here — wider laps are the safer choice on a floor you will walk on.

What thickness vapor barrier do I need for a crawl space?

The code asks for a Class I vapor retarder — a permeance of 0.1 perm or less — and does not name a thickness. Six-mil polyethylene is the usual minimum for a ground cover; 10 and 20 mil reinforced liners are more puncture-resistant. Check the liner data sheet for its ASTM E1745 class.

How many rolls of vapor barrier do I need?

Divide the liner with waste by the roll area and round up. Common rolls are 10, 12 and 20 feet wide by 100 feet long — 1,000, 1,200 and 2,000 sq ft. Wider rolls mean fewer seams but are heavier to carry into the space.

How much seam tape and termination bar do I need?

Tape covers the seams plus the perimeter edge seal — about 1 roll of 180 ft per 1,000 sq ft of liner. Termination bar comes in 42 inch pieces along the perimeter (perimeter / 3.5), with fasteners every 6 inches, or 2 per foot of perimeter.

Is a crawl space vapor barrier the same as house wrap?

No. House wrap is an above-grade wall wrap with a different material and code section — it lets water out while blocking rain. A crawl space liner is a ground-cover Class I retarder that seals soil moisture in. See the House Wrap Calculator for walls.