Rigid Foam Insulation Calculator
A 30 by 8 foot wall needs 9 sheets of 4 by 8 foot rigid foam — one layer of 2 inch XPS gives R-10. Enter your wall below for your sheet count and R-value.
Planning estimate, not professional advice: energy codes set minimum insulation by climate zone and many states amend them — this page does not reproduce the IECC table, so enter the figure from your local code as the target R-value. Two layers with staggered seams reduce heat loss through the joints and are easier to carry and cut. Polyiso can lose R-value in cold weather, so use the lower label value for cold climates. Check the label on the board you buy — R per inch varies by brand and density.
How the rigid foam insulation calculator works
Rigid foam is sold by the sheet, so the count is area times layers times a waste allowance, divided by the area of one sheet: sheets = area x layers x (1 + waste%) / sheet area, rounded up. A 4 by 8 foot sheet covers 32 sq ft, a 2 by 8 foot sheet 16 sq ft. The R-value of the assembly is thickness times R per inch for each layer, added: EPS is about R-4 per inch, XPS about R-5 per inch and polyiso about R-6 per inch. If you enter a target R-value, the layers are the target divided by the R-value of one layer, rounded up — two layers with staggered seams cut seam leakage and are easier to carry and cut than one thick layer.
Worked example: a 30 by 8 foot wall is 240 sq ft. With 10% waste that is 264 sq ft; at 32 sq ft per sheet that is 9 sheets of 4 by 8 foot board, or 17 sheets of 2 by 8. One layer of 2 inch XPS is R-10 (2 x 5). To reach R-20 it takes two layers, and the sheet count doubles to 17. A 400 sq ft wall with a 10 percent allowance needs 14 sheets per layer. A 4 by 8 sheet that is 2 inches thick is 64 board feet, and foam board is priced by the board foot: one square foot, one inch thick.
Common mistakes: dividing by the gross wall area without deducting windows and doors (a wall with many openings can over-order by a whole sheet or two); using the polyiso label R-value in a cold climate, where it can lose R-value — use the lower label value; and forgetting that energy codes set the minimum by climate zone, so the target R-value on this page must come from your local code, not from this calculator. Foam inside the house needs a thermal barrier — typically 1/2 inch drywall — over it, per code. For batts and rolls, use the Roll & Batt Insulation Calculator; for blown-in, the Blown-In Insulation Calculator.
sheets = ceil(area x layers x (1 + waste%) / sheet area) · total R = thickness x R per inch x layers · layers from target = ceil(target R / R per layer) · EPS R-4, XPS R-5, polyiso R-6 per inch · 4x8 sheet = 32 sq ft
Related tools
Also try the Roll & Batt Insulation Calculator for batts, the Blown-In Insulation Calculator for loose-fill, and the House Wrap Calculator for the air barrier.
Rigid foam insulation calculator FAQ
How many sheets of rigid foam board do I need?
Divide your area in square feet by the sheet area (32 for a 4 ft by 8 ft sheet), add a cutting allowance, and round up. Then multiply by the number of layers. A 400 sq ft wall with a 10 percent allowance needs 14 sheets per layer.
What R-value is rigid foam board per inch?
EPS is about R-4 per inch, XPS about R-5 per inch and polyiso about R-6 per inch. Polyiso can lose R-value in cold weather, so use the lower label value for cold climates. Check the label on the board you buy.
How many layers of rigid foam do I need for R-20?
Divide the target by the R-value of one layer and round up. At 2 inches of XPS (R-10 per layer) you need 2 layers for R-20. At 1 inch of polyiso (R-6 per layer) you need 4 layers.
What size are rigid foam insulation sheets?
Most rigid foam comes as 4 by 8 foot sheets (32 sq ft) or 2 by 8 foot sheets (16 sq ft). The 4 by 8 size has the fewest seams; the 2 by 8 size is easier to carry and fits between wall studs or furring.
How much waste should I add for rigid foam insulation?
10% is the standard cutting allowance for open walls; use 15% for walls with many cuts, openings or staggered joints. Two layers with staggered seams reduce heat loss through the joints.
Do I need a vapor barrier with rigid foam insulation?
Foam board itself is a vapour retarder in most thicknesses, but the assembly still needs a thermal barrier — typically 1/2 inch drywall — over foam inside the house, per code. Check your local code for the exact requirement.
Is rigid foam better than fiberglass batts?
They do different jobs: batts fill the stud cavity, rigid foam goes continuous over the outside (or under the slab) and breaks the thermal bridging through the studs. Many assemblies use both — batts in the cavity plus continuous rigid board outside.