SwiftTools

Wire Mesh Calculator

A 20 by 20 foot slab needs 10 sheets of 6×6 mesh — not the 8 you get from dividing 400 by 50, because the lap eats about 15% of every sheet. Enter your slab below for the sheet count, weight and cost.

Your slab
effective coverage = (sheet width − lap) × (sheet length − lap) · pieces = ceil(area ÷ effective coverage × (1 + waste)) · a 5 × 10 ft sheet covers 42.75 sq ft at a 6 in lap, not 50

The lap is the part most calculators miss. Welded wire sheets have to overlap — butting them edge to edge leaves the reinforcement discontinuous exactly at the joint, where a crack will form. ACI 318 calls for a lap of one mesh spacing plus 2 inches, or 6 inches, whichever is greater: on 6×6 mesh that is 8 inches, on 4×4 mesh 6 inches. This calculator defaults to 6 inches, the figure most takeoffs use; at the ACI 8-inch lap a 5 × 10 ft sheet covers 40.4 sq ft and the same 20 × 20 ft slab takes 11 sheets instead of 10. Change the lap field to match your engineer or inspector.

This page counts mesh — it does not choose it. Which mesh a slab needs is a structural decision: W2.0 is the usual minimum for vehicle loads, W1.4 suits patios and sidewalks, and a slab 6 inches or thicker may need two layers. Planning estimate, not a substitute for professional approval: confirm the designation, the lap and the placement — mesh on chairs in the middle of the slab, not lying on the ground — with your engineer or local code.

How the wire mesh calculator works

A 5 by 10 ft sheet is 50 square feet nominal, but it never covers 50 square feet of slab. Welded wire sheets have to overlap at every joint, so one lap comes out of the effective coverage in each direction: at a 6-inch lap, a 5 by 10 ft sheet covers 4.5 by 9.5 ft, or 42.75 square feet. Pieces equals slab area divided by that effective coverage, times one plus the waste allowance, rounded up. On the default slab — 20 by 20 ft, 400 square feet — that is 400 / 42.75 = 9.36, and with the 5% offcut allowance 9.82, so buy 10 sheets.

The lap size is the whole argument. ACI 318 calls for a lap of one mesh spacing plus 2 inches, or 6 inches, whichever is greater — on 6×6 mesh that is 8 inches, which leaves a 5 by 10 ft sheet covering 40.4 square feet, and the same 20 by 20 ft slab takes 11 sheets. Most takeoffs use 6 inches, which is the figure this calculator defaults to, but if your engineer or inspector calls for the ACI 8-inch lap, type 8 in the lap field and the count follows. The difference is one sheet on a 400 sq ft slab and grows with the slab.

The mesh designation reads like a code. Under ASTM A1064, 6×6-W2.0 means wires every 6 inches in both directions, with a wire area of 0.02 square inches (the W number is hundredths of a square inch). Heavier wire weighs more per square foot: W1.4 is about 0.21 lb per sq ft, W2.0 about 0.29, W2.9 about 0.42. The default slab in W2.0 buys 500 square feet of mesh — 10 sheets at 50 sq ft — which weighs 145 lb. Rolls work the same way: a 5 by 150 ft roll covers 750 sq ft nominal, 672.75 after a 6-inch lap, so one roll covers the default slab with room to spare.

Worked example at a larger scale: a 24 by 20 ft slab is 480 square feet. At a 6-inch lap the effective coverage is still 42.75 sq ft per sheet, so 480 / 42.75 = 11.23, and with 10% waste 12.35 — buy 13 sheets of 5 by 10 ft, or 4 large 8 by 20 ft sheets. A whole-sheet grid laid with no offcuts reused needs a couple more than the area count, so keep the offcuts for the edges instead of cutting fresh sheets.

Common mistakes: dividing the slab area by the nominal sheet size and ordering 8 sheets for a 400 sq ft slab, then running a sheet short at the last joint; butting the sheets edge to edge with no lap, which leaves the reinforcement discontinuous exactly where a crack will form; and leaving the mesh lying on the ground instead of supporting it on chairs or dobies in the middle of the slab — mesh at the bottom of a slab does almost nothing, and mesh pulled up by the pour ends up in the wrong place. Keep it off the slab edge too: mesh stops a couple of inches short of the form.

effective coverage = (sheet width - lap) x (sheet length - lap) · pieces = ceil(area / effective coverage x (1 + waste)) · 5x10 sheet: 50 sq ft nominal, 42.75 at 6 in lap, 40.4 at 8 in lap · W1.4 0.21, W2.0 0.29, W2.9 0.42 lb/sq ft

Related tools

Size the slab itself with the Concrete Slab Calculator, count the bags with the Concrete Bags Calculator, and the cubic yards with the Concrete Cubic Yard Calculator. Keep a fresh slab damp while it cures with the Concrete Curing Water Calculator.

Wire mesh calculator FAQ

How many sheets of wire mesh do I need for a slab?

Divide the slab area by the effective coverage of one sheet — nominal size minus the lap in each direction — then add waste and round up. A 20 by 20 ft slab (400 sq ft) at a 6 in lap needs 400 / 42.75 = 9.36, or 10 sheets with the 5% allowance.

Why does a 5 by 10 sheet not cover 50 square feet?

Because the sheets have to overlap. At a 6-inch lap a 5 by 10 ft sheet covers 4.5 by 9.5 ft, or 42.75 sq ft — about 15% less than nominal. At the ACI 8-inch lap for 6x6 mesh it covers 40.4 sq ft.

What lap do I need for wire mesh?

ACI 318 calls for one mesh spacing plus 2 inches, or 6 inches, whichever is greater: 8 inches on 6x6 mesh, 6 inches on 4x4 mesh. Most takeoffs use 6 inches; if your engineer or inspector calls for the ACI lap, type it in the lap field.

What does 6x6-W2.0 mean?

Under ASTM A1064, the first pair is the wire spacing in inches (6 by 6) and the W number is the wire area in hundredths of a square inch (W2.0 = 0.02 sq in). Heavier W numbers mean heavier wire: W1.4 is about 0.21 lb per sq ft, W2.0 about 0.29, W2.9 about 0.42.

Sheets or rolls — which should I buy?

Sheets for small slabs and patios, where a 5 by 10 ft sheet is easy to carry and place; rolls for large slabs and driveways, where one 5 by 150 ft roll covers 750 sq ft and leaves fewer joints. The calculator counts both the same way, with the lap taken out of the coverage.

Where does the mesh go in the slab?

In the middle of the slab, supported on chairs or dobies — not lying on the ground and not pulled up by the pour. Mesh at the bottom of a slab does almost nothing. Keep it a couple of inches short of the form edge.

Wire mesh or rebar — which is better?

Mesh controls cracking and holds a slab together once it cracks; rebar carries structural loads. A patio or sidewalk usually takes mesh, a structural slab takes rebar, and a driveway often takes both. Which one a slab needs is a structural decision, not a quantity one.