Joist Hanger Calculator
Enter your joist run, spacing and joist size, and this joist hanger calculator returns the hangers to buy, the hanger model for that joist size, and the hanger nails — using the nail schedule from the Simpson Strong-Tie catalog.
Planning estimate only — this is not structural design. Hanger models and nail schedules are from the Simpson Strong-Tie Wood Construction Connectors catalog C-C-2026 (LUS series, single 2x hangers). Verify the model against the current catalog for the exact hanger you buy, and confirm the layout with your local building code or a licensed structural engineer before you build.
How the joist hanger calculator works
The count is the same spaces-plus-one rule used in every framing layout. Divide the run length in inches by the joist spacing to get the whole spaces, and add one joist for the start of the run. Each joist takes one hanger at each hung end: one hanger where the joist meets a ledger and the other end bears on a beam, or two where both ends are hung. The hanger model follows the joist size — LUS24 for 2x4, LUS26 for 2x6, LUS28 for 2x8 and LUS210 for 2x10 in the Simpson Strong-Tie LUS face-mount series — and the nail schedule follows the model: the joist nails stay at 4 across the series while the header nails grow from 4 to 8 as the hanger gets taller.
Worked example: a 16-foot ledger at 16 inches on centre with 2x8 joists, one end hung, is 192 inches divided by 16, or 12 spaces, so the run takes 13 joists and 13 hangers. The 2x8 selects the LUS28, at 10 nails per hanger (6 into the header, 4 into the joist), so the run needs 130 nails in total: 78 header nails and 52 joist nails. With 10% waste that is 15 hangers and 143 nails, about $37.50 at $2.50 a hanger. A 20-foot ledger at the same spacing takes 16 joists and 16 hangers, or 160 nails.
Common mistakes: forgetting the plus-one joist, which leaves the last bay without a hanger; using deck screws or roofing nails as hanger fasteners — they are not substitutes and will fail inspection, because hanger nails are 10d by 3-inch (0.148-inch) nails driven at an angle through the joist into the header for double-shear nailing, and every hole must be filled; and picking a hanger by price instead of by joist depth — a 2x4 hanger on a 2x8 joist is a safety hazard. This is a planning estimate, not structural design: verify the model against the current manufacturer catalog and your local code before you build. The Deck Joist Span Calculator sizes the joists these hangers hold.
joists = floor(run in inches / spacing) + 1 · hangers = joists x hung ends · nails = hangers x (header nails + joist nails) · LUS24 4+2, LUS26 4+4, LUS28 6+4, LUS210 8+4
Related tools
Also try the Deck Joist Span Calculator for the joists, the Floor Joist Span Calculator for indoor floors, and the Ceiling Joist Span Calculator for ceilings.
Joist hanger calculator FAQ
How many joist hangers do I need?
One per hung joist end. Count the joists — run length in inches divided by spacing, plus one — then multiply by 1 if only the ledger end is hung, or by 2 if both ends are hung. A 16-foot deck at 16 inches on centre takes 13 joists and 13 or 26 hangers.
What size joist hanger do I need for a 2x8?
The LUS28 in the Simpson Strong-Tie LUS series: it takes 6 nails into the header and 4 into the joist, all 10d by 3-inch nails, for 10 nails per hanger. Match the hanger to the joist depth — a 2x4 hanger on a 2x8 joist is a safety hazard.
How many nails go in a joist hanger?
It depends on the model: LUS24 takes 6 nails (4 header, 2 joist), LUS26 takes 8 (4 and 4), LUS28 takes 10 (6 and 4), and LUS210 takes 12 (8 and 4). Every hole must be filled to reach the published load.
Can I use deck screws instead of hanger nails?
No. Deck screws and roofing nails are not hanger fasteners and will fail inspection. Hanger nails are 10d by 3-inch (0.148-inch) nails, driven at an angle through the joist into the header for double-shear nailing. Listed structural-connector screws are the approved alternative.
Do I need a hanger on both ends of every joist?
Only where the joist end is hung from a ledger or a flush beam. Where the joist bears on top of a beam or wall, it needs no hanger — a hurricane or seismic tie instead where the code calls for one. Cantilevered joists hang at the beam and extend past it.
How many joists are in a 16-foot run?
At 16 inches on centre: 192 divided by 16 is 12 spaces, plus one for the start of the run, or 13 joists. The plus-one is the classic off-by-one error — skip it and the last bay comes up short.
Are joist hanger loads the same for every wood species?
No. The published allowable loads in the Simpson catalog vary by header species — a LUS210 on a Southern pine header is rated well above the same hanger on spruce-pine-fir. Check the catalog column for your species before relying on a load figure.