Roofing Felt Calculator
Enter your roof size and pitch, and this roofing felt calculator returns the sloped roof area, the layers the code calls for, and the rolls of felt or synthetic underlayment to buy.
Planning estimate: enter the full footprint including overhangs — a roof with a 12-inch overhang is bigger than the house below it. Low-slope roofs (2/12 to under 4/12) need two layers of underlayment under asphalt shingles per IRC R905. Ice-and-water shield at the eaves and in valleys is extra and is not counted here. Check the roll label — coverage varies by manufacturer.
How the roofing felt calculator works
Felt is sold by net coverage per roll, with the laps already allowed for: a roll of #15 felt covers about 400 square feet (4 squares), a roll of #30 felt about 200 square feet (2 squares), and a roll of synthetic underlayment about 1,000 square feet. The count is the sloped roof area — the flat footprint times the pitch factor, the square root of 1 plus the rise-over-12 squared — times the number of layers, plus waste, divided by the roll coverage and rounded up.
Worked example: a 40 by 30 foot roof at 6/12 pitch has a pitch factor of 1.118, so the sloped area is 1,200 times 1.118, or 1,342 square feet (13.4 squares). One layer at 4/12 and steeper is enough, and with 10% waste for a gable roof that is 1,476 square feet to cover — 1,476 divided by 400 rounds up to 4 rolls of #15 felt, about $100 at $25 a roll. The same roof in #30 felt needs 8 rolls.
Common mistakes: measuring the flat footprint instead of the sloped area (a 12/12 roof needs 41% more underlayment than its footprint); using one layer on a low-slope roof — IRC R905 calls for two layers from 2/12 up to but not including 4/12; and forgetting that hips and valleys waste more felt than a plain gable (15% waste on a hip roof against 10% on a gable). Ice-and-water shield at the eaves and in valleys is a separate product and is not counted here. The Roof Shingle Bundle Calculator sizes the shingles that go over the felt.
pitch factor = sqrt(1 + (rise / 12)²) · roof area = length x width x pitch factor · layers = 2 below 4/12 pitch, 1 at 4/12 and steeper · rolls = ceil(roof area x layers x (1 + waste%) / coverage per roll)
Related tools
Also try the Roof Shingle Bundle Calculator for the shingles, the Roof Pitch Calculator for the pitch factor, and the Roof Replacement Cost Calculator for the whole job.
Roofing felt calculator FAQ
How many rolls of felt do I need for a 2,000 sq ft roof?
About 6 rolls of #15 felt (2,000 times 1.10, divided by 400, rounded up) or 11 rolls of #30 felt at 200 square feet per roll. A hip roof at 15% waste needs 6 rolls of #15 and 12 of #30.
What is the difference between #15 and #30 roofing felt?
#15 felt is lighter (about 400 sq ft per roll) and the usual pick under asphalt shingles; #30 felt is heavier and thicker (about 200 sq ft per roll) and is used under tile, on low slopes, or where extra durability is wanted.
How many square feet does a roll of synthetic underlayment cover?
About 1,000 square feet per roll — roughly two and a half times a roll of #15 felt. Synthetic is lighter, tears less, and stays walkable when wet, but check the roll label: sizes vary by manufacturer.
When do I need two layers of underlayment?
On low-slope roofs from 2/12 up to but not including 4/12 pitch, under asphalt shingles (IRC R905.1.1 and R905.2.7). At 4/12 and steeper, one layer is enough. Below 2/12, shingles are not allowed at all.
How do I work out the sloped area of my roof?
Multiply the footprint (length times width, including overhangs) by the pitch factor: the square root of 1 plus the rise-over-12 squared. At 6/12 the factor is 1.118, so a 1,200 sq ft footprint is 1,342 sq ft of roof.
Do I need ice-and-water shield too?
In areas where ice forms along the eaves, code requires an ice barrier at least 24 inches inside the exterior wall line (IRC R905.1.2). It is a separate self-adhering membrane and is not counted in the felt rolls above.
How much waste should I allow for roofing felt?
About 10% on a gable roof, 15% on a hip roof, and 8% on a simple shed roof. Complex roofs with many valleys and dormers need more — the cuts along every hip are angled and the offcuts rarely fit elsewhere.