Soffit Calculator

A 40 by 30 foot house with 80 feet of eave and 36 feet of boxed rake needs 14 vinyl soffit panels covering 143 square feet, plus 116 feet of fascia. Enter your eave and rake runs below for panels, trim, and the attic vent check.

Your eaves
soffit area = eave × overhang ÷ 12 + rake × rake overhang ÷ 12 · panels = ceil(area × (1 + waste) ÷ panel coverage) · required NFA = attic ÷ ratio × 144 sq in

Panels are cut across the overhang, from the wall to the fascia, so a 12 ft panel yields 9 pieces at a 16-inch overhang — the area method plus 10% waste covers the offcuts on a straight gable house. On a hip roof, add a few extra panels for the mitered corners. Fascia is a separate linear takeoff on this page, not a separate calculator. Check the width and length of the panel you buy — vinyl is commonly 12 in wide by 12 ft, aluminum 16 in by 12 ft, and plywood comes as 4 x 8 ft sheets.

Planning check — not a code approval. IRC R806.2 asks for 1 sq ft of net free vent area per 150 sq ft of attic floor, dropping to 1:300 only where the vapour-retarder exception is met (a Class I or II vapour retarder on the warm side of the ceiling in climate zones 6–8, with 40–50% of the area high, within 3 ft of the ridge). Only eave soffit counts as intake — a boxed rake gives no air path. Confirm the code edition your area adopted.

How the soffit calculator works

A soffit takeoff has two jobs at once: a materials job — how much panel and trim to buy — and an air job — how much open vent area the installed panels actually deliver. The area is eave length times overhang depth, plus boxed rake length times rake overhang: an 80 ft eave at 16 inches is 80 x 16 / 12 = 106.67 square feet, and a 36 ft boxed rake at 12 inches adds 36 square feet, for 142.67 square feet in total. Panels are that area times waste, divided by the coverage of one panel — a standard 12 in by 12 ft vinyl panel covers 12 square feet, so 142.67 x 1.10 / 12 = 13.08, rounded up to 14 panels.

The cut list is why the waste allowance matters. Soffit panels run across the overhang, from the wall to the fascia, so each 12 ft panel is cut into short pieces — 9 pieces of 15 1/2 inches at a 16-inch overhang, after the 1/2-inch expansion allowance. Dividing area by 12 square feet per panel undercounts, because the offcuts are waste; the 10% allowance covers them on a straight gable house. Hip roofs need more: each outside corner takes two extra pieces per panel width of depth, miter-cut from both sides.

Fascia and channel are linear takeoffs on the same page. Fascia is the eave plus rake length — 116 feet on the example house, or 10 twelve-foot boards. J-channel or F-channel runs twice, once at the wall and once at the fascia side, so 232 feet, or 20 twelve-foot lengths. Trim coil for wrapping fascia is bent on site into strips the face height plus about 2.5 inches wide, for the tuck under the drip edge and the bottom hem.

Ventilation is the check that catches most first takeoffs. IRC R806.2 asks for 1 square foot of net free vent area per 150 square feet of attic floor — 1,200 square feet of attic needs 1,152 square inches in total, and about half of that, 576 square inches, should be intake at the soffit. All-vented vinyl panels rated 5.3 square inches per foot supply 80 x 5.3 = 424 square inches on the example house, which is short of 576 — so that house needs more vented panels, a higher-NFA panel, or added intake vents. Only eave soffit counts as intake; a boxed rake gives no air path.

Common mistakes: counting the rake as vent area, when it is sealed; using the 1:300 ratio without meeting the exception — it needs a Class I or II vapour retarder on the warm side of the ceiling in climate zones 6 to 8, with 40 to 50% of the vent area high, within 3 feet of the ridge; and ordering panels by area alone on a hip roof, where the corner miters eat the allowance. When in doubt, use 1:150 and buy two spare panels.

area = eave x overhang / 12 + rake x rake overhang / 12 · panels = ceil(area x (1 + waste) / panel coverage) · required NFA = attic / 150 x 144 sq in, half of it intake

Related tools

Size the whole attic system with the Attic Ventilation Calculator, check the pitch with the Roof Pitch Calculator, and count the gutters with the Gutter Downspout Calculator. The wall below the eave is the Vinyl Siding Calculator.

Soffit calculator FAQ

How many soffit panels do I need?

Divide the soffit area by the coverage of one panel, after adding waste. A 40 by 30 ft house with 80 ft of eave and 36 ft of boxed rake needs 14 vinyl panels (12 in by 12 ft) covering 143 square feet with the 10% cutting allowance.

What size are soffit panels?

Vinyl soffit is commonly sold as 12 in wide by 12 ft long panels — 12 square feet each — in Triple 4 and Double 5 profiles. Aluminum is often 16 in by 12 ft, or 16 square feet per panel. Check the width and length of the panel you buy.

How much J-channel do I need for soffit?

Two runs — one at the wall, one at the fascia — so twice the total eave and rake length. A house with 116 ft of eave plus rake needs 232 ft of J-channel or F-channel, or 20 twelve-foot lengths.

How much fascia do I need?

The eave length plus the boxed rake length, in linear feet — 116 ft on the example house, or 10 twelve-foot boards. Fascia is a separate linear takeoff from the soffit panels, but it belongs on the same order.

How much soffit vent area does my attic need?

IRC R806.2 asks for 1 sq ft of net free area per 150 sq ft of attic floor, with about half of it as intake at the soffit. A 1,200 sq ft attic needs 1,152 sq in total and 576 sq in of intake — all-vented panels at 5.3 sq in per foot supply 424 sq in on an 80 ft eave, which is short.

Vented or solid soffit panels?

Use vented panels where intake is needed — usually the eaves — and solid panels elsewhere, such as gable ends and porch ceilings. Mix them by the piece: the vent check on this page tells you how much vented area you actually need.

Is soffit the same as fascia?

No. The soffit is the horizontal underside of the overhang, between the wall and the fascia; the fascia is the vertical board at the roof edge covering the rafter ends. They are ordered together but measured differently — area for soffit, linear feet for fascia.