Greenhouse Size Calculator
100 plants at 4 sq ft each plus a 30% aisle allowance need about 520 sq ft of floor — roughly a 22 × 24 ft footprint. Enter your plant count below for the footprint, heater size and ventilation.
The rafter length is rounded to 0.01 ft before the glazing area is worked out, so the published default check (1,165.2 sq ft of glazing) reproduces exactly. The footprint rounds up to even feet — a real greenhouse is built to whole-foot sizes. Planning estimates, not an engineering design: confirm sizes, snow and wind loads and heater choice with your supplier or contractor.
Heat escapes through the skin. The heater is sized on the glazing area, not the floor area — a tall greenhouse loses far more heat than a low one of the same footprint.
How the greenhouse size calculator works
The size is built from the plants, then the heater and ventilation are built from the size. On the default — 100 plants at 4 sq ft each, 30% aisle allowance, 6 ft eave, 9 ft ridge, double poly, 65 F inside and 25 F outside — the growing area is 100 x 4 = 400 sq ft and the floor is 400 x 1.30 = 520 sq ft. The footprint rounds up to even feet: width 2 x ceil(sqrt(520 / 1.2) / 2) = 22 ft, length 2 x ceil((520 / 22) / 2) = 24 ft, for 528 sq ft. The rafter is the square root of ((22/2) squared + (9 - 6) squared) = 11.40 ft. Glazing is 2(22 x 6) + 2(24 x 6) + 2(24 x 11.40) + 22 x 3 = 1,165.2 sq ft. The temperature difference is 40 F, so the heater output is 1,165.2 x 0.80 x 40 = 37,286 BTU/hr and the heater input at 80% efficiency is 37,286 / 0.80 = 46,608 BTU/hr. Volume is 24 x 22 x 7.5 = 3,960 cu ft, so ventilation is 3,960 CFM at 1 air change a minute, the roof vent is at least 15% of the 528 sq ft footprint = 79.2 sq ft, and water is 100 x 0.75 = 75 gal a day.
The worked example sizes a small greenhouse the same way. An 8 by 10 foot greenhouse has 80 sq ft of floor; with a 25% aisle allowance that leaves 80 x 0.75 = 60 sq ft of growing area, or about 15 plants at 4 sq ft each. The aisle allowance is the difference between the floor you build and the plants you grow — skip it and the beds fill the whole house with nowhere to walk.
The cross-check is the nrtechstudio one, and it confirms the heater formula at a second size. A 1,000 sq ft greenhouse with double poly glazing and a 40 F temperature difference needs 1,000 x 0.80 x 40 = 32,000 BTU/hr — the same glazing x U-value x temperature-difference formula this calculator uses, applied to a round number. Change any one of the three — more glazing, a worse U-value, a colder night — and the heater size moves in proportion.
Count the plants you grow at once, not over the season — succession planting reuses the same bench. Space per plant depends on the crop: 4 sq ft suits tomatoes and peppers, leafy greens take far less, and the field is yours to set. Aisle percentage covers paths and working space: 30% is the default, more if you push a wheelbarrow through. Eave and ridge heights set the roof slope and the volume — a taller house holds more air to heat and to move. Glazing U-value sets heat loss: single glass 1.25, double poly 0.80, twin-wall 0.70, triple-wall 0.60. Inside and outside temperatures set the difference the heater must cover on the coldest night you design for.
Common mistakes: sizing the heater on floor area instead of glazing area — heat escapes through the skin, not the floor, so a tall greenhouse needs far more heat than a low one of the same footprint; forgetting the aisle allowance and building a greenhouse you cannot walk in; undersizing ventilation — 1 air change a minute is the planning figure, and the roof vent alone must be at least 15% of the footprint; and treating these as an engineering design — snow and wind loads, heater choice and glazing fixings all need confirming with your supplier or contractor.
growing area = plants x space per plant · floor = growing area x (1 + aisle%) · width = 2 x ceil(sqrt(floor/1.2)/2), length = 2 x ceil((floor/width)/2), both even feet · rafter = sqrt((width/2) squared + (ridge-eave) squared), rounded to 0.01 ft · glazing = 2(width x eave) + 2(length x eave) + 2(length x rafter) + width x (ridge-eave) · volume = length x width x (eave+ridge)/2 · heater output = glazing x U x (inside-outside) · heater input = output / 0.80 · ventilation = volume x 1 air change/min · roof vent >= 15% of footprint · water = plants x 0.75 gal/day
Related tools
Frame the beds inside it with the Raised Garden Bed Lumber Calculator, price the soil with the Raised Bed Soil Calculator, space the plants with the Plant Spacing Calculator, water them with the Drip Irrigation Calculator, and feed them with the Compost Calculator.
Greenhouse size calculator FAQ
How big a greenhouse do I need for 100 plants?
About 520 sq ft of floor — roughly a 22 x 24 ft footprint — at 4 sq ft per plant with a 30% aisle allowance.
How many plants fit in an 8x10 greenhouse?
About 15 at 4 sq ft each: 80 sq ft of floor with a 25% aisle allowance leaves 60 sq ft of growing area.
How many BTU do I need to heat a greenhouse?
Glazing area x U-value x temperature difference: 1,165.2 sq ft of double poly x 0.80 x 40 F = 37,286 BTU/hr output, or a 46,608 BTU/hr heater at 80% efficiency.
How much ventilation does a greenhouse need?
About 1 air change a minute — 3,960 CFM for the default 3,960 cu ft greenhouse. Size fans on volume, not floor area.
How big should the roof vents be?
At least 15% of the footprint: 79.2 sq ft for the default 22 x 24 ft greenhouse. Ridge vents plus side vents cool far better than either alone.
How much water do greenhouse plants use?
About 0.75 gal per plant per day as a planning figure — 75 gal a day for 100 plants. Hot, sunny days use more; drip irrigation wastes least.
How wide should greenhouse aisles be?
The 30% aisle allowance covers 2–3 ft main paths plus working space around the beds. Allow more if you push a wheelbarrow through, less for narrow single-row houses.